Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.194
Filtrar
2.
Kyobu Geka ; 77(1): 35-37, 2024 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-38459843

RESUMO

Oral anticoagulants for atrial fibrillation are the standard approach to prevent stroke in patients with atrial fibrillation. However, oral anticoagulant therapy carries the risk of cerebral infarction recurrence, not to mention hemorrhagic complications, even under appropriate drug therapy. Surgical treatments targeting the left atrial appendage include left atrial appendage closure( LAAO) and left atrial appendage resection (LAAR). Our hospital uses AtriClip (approved and available in Japan since 2018) as a device for LAAO, and we investigated the early and long-term results of LAAO using AtriClip in our hospital. As a result, stable early to long-term results were expected for left atrial appendage closure using AtriClip device, suggesting that it may be an option that can be considered as a method for preventing stroke in patients with atrial fibrillation. But further investigation is required in the future.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , 60589 , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/uso terapêutico , Instrumentos Cirúrgicos/efeitos adversos , Resultado do Tratamento
3.
Int J Med Robot ; 20(2): e2624, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430543

RESUMO

BACKGROUND: The aim of this study was to investigate 8-mm robotic trocar site hernia (TSH) rate over the short and long term, providing aids to manage the related fascial wounds. METHODS: A retrospective analysis of 320 patients undergoing robotic surgery was conducted. The primary outcome was 8-mm TSH rate with a minimum follow-up of 12 months. The secondary outcome was the rate of haematomas and infections related to 8-mm wounds and their association with patient comorbidities and trocar position. RESULTS: One case of TSH was observed (0.31%). There were 15 cases of wound infection (4.68%) and 22 cases of wound haematoma (6.87%). Trocar related complications were significantly associated with patient comorbidities, not with trocar position. CONCLUSIONS: Our results do not justify the 8-mm fascial wound closure. Data concerning the association between trocar-related complications and patient comorbidities strengthen the need to implement the control of metabolic state and correct administration of perioperative therapy in high-risk patients.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Tireotropina
4.
Sci Rep ; 14(1): 3583, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351278

RESUMO

Analyses of registries and medical imaging suggest that laparoscopic surgery may be penalized with a high incidence of trocar-site hernias (TSH). In addition to trocar diameter, the location of the surgical wound (SW) may affect TSH incidence. The intra-abdominal pressure (IAP) exerted on the abdominal wall (AW) might also influence the appearance of TSH. In the present study, we used finite element (FE) simulations to predict the influence of trocar location and SW characteristics (stiffness) on the mechanical behavior of the AW subject to an IAP. Two models of laparoscopy patterns on the AW, with trocars in the 5-12 mm range, were generated. FE simulations for IAP values within the 4 kPa-20 kPa range were carried out using the Code Aster open-source software. Different stiffness levels of the SW tissue were considered. We found that midline-located surgical wounds barely deformed, even though they moved outwards along with the regular LA tissue. Laterally located SWs hardly changed their location but they experienced significant variations in their volume and shape. The amount of deformation of lateral SWs was found to strongly depend on their stiffness. Trocar incisions placed in a LA with non-diastatic dimensions do not compromise its mechanical integrity. The more lateral the trocars are placed, the greater is their deformation, regardless of their size. Thus, to prevent TSH it might be advisable to close lateral trocars with a suture, or even use a prosthetic reinforcement depending on the patient's risk factors (e.g., obesity).


Assuntos
Parede Abdominal , Laparoscopia , Humanos , Parede Abdominal/cirurgia , Fenômenos Biomecânicos , Cicatriz/etiologia , Laparoscopia/efeitos adversos , Instrumentos Cirúrgicos/efeitos adversos , Tireotropina
5.
Hernia ; 28(2): 585-592, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319439

RESUMO

INTRODUCTION: With an incidence of 0-5.2%, trocar site hernias frequently occur following laparoscopy. It is unclear to what extent the angle of trocar insertion affects the size of the fascial defect caused. Hence, we performed a porcine model. METHODS: In October 2022, a total of five female pigs were euthanized. In alternating order, three bladeless and two bladed conical 12-mm trocars were inserted at an angle of 45° on each side for 60 min twice each pig. For this purpose, an epoxy resin handmade cuboid with a central channel that runs at an angle of 45° was used. Subsequently, photo imaging and defect size measurement took place. The results were compared with those of our previously conducted and published porcine model, in which the trocars were inserted at an angle of 90°. Effects of trocar type (bladed vs. bladeless) and angle on defect size were analyzed using a mixed model regression analysis. RESULTS: The bladeless trocars caused statistically significant smaller defects at the fascia than the bladed (23.4 (SD = 16.9) mm2 vs. 41.3 (SD = 14.8) mm2, p < 0.001). The bladeless VersaOne trocar caused the smallest defect of 16.0 (SD = 6.1) mm2. The bladed VersaOne trocar caused the largest defect of 47.7 (SD = 10.5) mm2. The defect size of the trocars used at a 45° angle averaged 30.5 (SD = 18.3) mm2. The defect size of trocars used at a 90° angle was significantly larger, averaging 58.3 (SD = 20.2) mm2 (p = 0.007). CONCLUSION: When conical 12-mm trocars are inserted at a 45° angle, especially bladeless ones, they appear to cause small fascial defects compared with insertion at a 90° angle. This might lead also to a lower rate of trocar hernias. Bladeless trocars might cause smaller fascial defects than bladed trocars.


Assuntos
Herniorrafia , Laparoscopia , Feminino , Suínos , Animais , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Fáscia , Hérnia
6.
Laryngoscope ; 134(1): 103-107, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37232539

RESUMO

OBJECTIVE: To understand the etiology of tracheotomy-induced tracheal stenosis by comparing the differences in techniques and mechanical force applied with open tracheotomy (OT) versus percutaneous tracheotomy (PCT) placement. METHODS: This study is an unblinded, experimental, randomized controlled study in an ex-vivo animal model. Simulated tracheostomies were performed on 10 porcine tracheas, 5 via a tracheal window technique (OT) and 5 using the Ciaglia technique (PCT). The applied weight during the simulated tracheostomy and the compression of the trachea were recorded at set times during the procedure. The applied weight during tracheostomy was used to calculate the tissue force in Newtons. Tracheal compression was measured by anterior-posterior distance compression and as percent change. RESULTS: Average forces for scalpel (OT) versus trocar (PCT) were 2.6 N and 12.5 N (p < 0.01), with the dilator (PCT) it was 22.02 N (p < 0.01). The tracheostomy placement with OT required an average force of 10.7 N versus 23.2 N (p < 0.01) with PCT. The average change in AP distance when using the scalpel versus trocar was 21%, and 44% (p < 0.01), with the dilator it was 75% (p < 0.01). The trach placement with OT versus PCT had an average AP distance change of 51% and 83% respectively (p < 0.01). CONCLUSION: This study demonstrated that PCT required more force and caused more tracheal lumen compression when compared to the OT technique. Based on the increased force required for PCT, we suspect there could also be an increased risk for tracheal cartilage trauma. LEVEL OF EVIDENCE: NA Laryngoscope, 134:103-107, 2024.


Assuntos
Estenose Traqueal , Traqueostomia , Traqueotomia , Animais , Instrumentos Cirúrgicos/efeitos adversos , Suínos , Traqueia/cirurgia , Traqueia/lesões , Estenose Traqueal/etiologia , Estenose Traqueal/cirurgia , Traqueostomia/efeitos adversos , Traqueostomia/métodos , Traqueotomia/efeitos adversos , Modelos Animais de Doenças
7.
Clin Neurol Neurosurg ; 236: 108058, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38056041

RESUMO

BACKGROUND: There is an ongoing lack of consensus among clinicians regarding on the optimal aneurysmal subarachnoid hemorrhage (aSAH) management approach between endovascular coiling and microsurgical clipping. METHODS: Comprehensive literature search for randomized controlled trials (RCTs) was conducted in Medline and Cochrane databases until January 1st, 2023 without language constraints. Effectivity outcomes included one-year mortality, one-year poor outcomes, and one-year complete aneurysmal occlusion, while safety outcomes comprised the incidence of vasospasms, rebleeding, post-operative complications, and cerebral ischemia. RESULTS: Eight RCTs, involving 3585 aSAH patients, underwent comprehensive quantitative analysis. Among them, 1792 underwent endovascular coiling and 1773 patients had microsurgical clipping. Regarding effectivity, the rates of one-year mortality (OR: 0.79, 95% CI: 0.61-1.03, p = 0.08) exhibited no significant difference. However, endovascular coiling demonstrated an inferior one-year complete aneurysmal occlusion rate (OR: 0.33, 95% CI: 0.21-0.53, p < 0.00001), although with significantly lower rates of poor outcomes (OR: 0.68, 95% CI: 0.57-0.81, p < 0.00001) compared to the microsurgical clipping group. As for safety, endovascular coiling group exhibited lower rates of vasospasm (OR: 0.58, 95% CI: 0.36-0.92, p = 0.02), post-operative complications (OR: 0.40, 95% CI: 0.23-0.71, p = 0.02), and cerebral ischemia (OR: 0.36, 95% CI: 0.20-0.63, p = 0.0004). No significant effect on the incidence of rebleeding was observed (OR: 1.09, 95% CI: 0.73-1.63, p = 0.68). CONCLUSIONS: Endovascular coiling proves superior and safer for aSAH patients, but consideration of resources, patient condition, and surgeon preferences is crucial for selecting the optimal approach.


Assuntos
Aneurisma Roto , Isquemia Encefálica , Procedimentos Endovasculares , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Aneurisma Intracraniano/complicações , Resultado do Tratamento , Instrumentos Cirúrgicos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Isquemia Encefálica/complicações , Infarto Cerebral/complicações , Aneurisma Roto/cirurgia
8.
Am J Otolaryngol ; 45(1): 104107, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37948825

RESUMO

OBJECTIVES: Topic treatment can be useful to improve short and long-term nasal outcomes after nasal surgery, reducing discomfort and risk of synechia. This study aimed at evaluating the effect on clinical outcomes of nasal packaging using Fitostimoline® gauze in FESS and septoplasty. METHODS: A case-control study on hospitalized patients was performed in a tertiary referral center. The control group included 20 patients treated with the standard surgical protocol for septoplasty and standard nasal packaging; treatment group included 21 patients underwent same surgical procedure but in whom the nasal tampon was wrapped with a gauze containing Fitostimoline® before being placed into the nose. RESULTS: Patients in treatment group had better outcomes than control; nasal mucosa showed better healing - recovery of normal color- in those patients in whom we applied the Fitostimoline® gauze around tampons. Moreover, 100 % patients in the treatment group did not refer discomfort during at tampon removal versus 60 % subjects in the control group who referred pain, tension or tearing during the same action. CONCLUSION: Our results, although preliminary because of the small cohort of subjects included, suggest that the apposition of a gauze with Fitostimoline® after nasal surgery might improve the mucosal healing with consequent reduction of patients discomfort during the post-surgical period.


Assuntos
Obstrução Nasal , Rinoplastia , Humanos , Estudos de Casos e Controles , Septo Nasal/cirurgia , Rinoplastia/métodos , Endoscopia/efeitos adversos , Instrumentos Cirúrgicos/efeitos adversos , Resultado do Tratamento , Obstrução Nasal/cirurgia
9.
J Clin Gastroenterol ; 58(1): 76-79, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728443

RESUMO

BACKGROUND: Clips are endoscopic mechanical devices with tensile and closure strength that can approximate tissue and provide hemostasis through a tamponade effect. Clips are ubiquitously used in endoscopic practice, and numerous studies have validated the clinical efficacy of clips, with recent guidelines recommending them as a first-line intervention for recurrent and persistent nonvariceal gastrointestinal bleeding. However, the safety profile for these devices has yet to be delineated, thus, we aim to investigate this feature by examining the adverse events reported to the Food and Drug Administration. METHODS: Postmarketing surveillance data from the Food and Drug Administration Manufacturer And User Facility Device Experience database were analyzed from January 2012 to January 2021. The Manufacturer And User Facility Device Experience database is a reporting software and does not independently verify the details of complications. RESULTS: Two thousand five hundred forty reports were issued, of which 287 were patient adverse events and 2766 were device problems. Activation, separation, and positioning issues were most common. No consequences or clinically significant impact on patients were seen in 1968 reports. Foreign bodies were seen in 97 cases, hemorrhage in 57 cases, tissue damage in 42 cases, embedded clips in tissues/plaques in 16 cases, perforation in 15 cases, lacerations in 6 cases, and infection in 3 cases. CONCLUSIONS: While the most commonly reported device problems involved activation, separation, and positioning, most patients were clinically unaffected. Moreover, perforation and infection were exceedingly rare, further highlighting the safety profile of endoscopic clips.


Assuntos
Endoscopia , Hemorragia Gastrointestinal , Humanos , Estados Unidos , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/etiologia , Resultado do Tratamento , Instrumentos Cirúrgicos/efeitos adversos , Bases de Dados Factuais
10.
Ulus Travma Acil Cerrahi Derg ; 29(11): 1255-1260, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37889033

RESUMO

BACKGROUND: The aim of this study was to investigate the incidence, risk factors, clinical presentation, and management of major vascular injuries during bariatric surgery, with a specific focus on the role of different access methods in abdominal cavity entry. METHODS: A nationwide survey was conducted among bariatric surgeons to assess the prevalence of major vascular injuries. A questionnaire was distributed to 365 surgeons through WhatsApp groups of two national bariatric surgery societies, with 76 surgeons completing the survey. The study population included general surgeons practicing bariatric surgery, and the questionnaire consisted of 12 questions. RESULTS: Among the participants, 16.9% reported experiencing a major vascular injury during bariatric surgery. The majority of injuries (75%) occurred at the trocar entrance, with the remaining cases during the dissection phase. Notably, 66.7% of surgeons used optical trocars for access, while 27.8% employed the Veress needle technique. Early detection varied, with 45% identifying the injury immediately and 30% recognizing it within three minutes. Most injuries (52.4%) were repaired laparoscopically, and only three surgeons sought assistance from cardiovascular surgeons. CONCLUSION: Vascular injuries are infrequent but potentially serious complications in laparoscopic bariatric surgery. Understand-ing their incidence, timely recognition, and proper management are crucial to minimize adverse effects. The findings of this study shed light on the patterns of vascular injuries and the potential role of specific access methods, providing valuable insights for enhancing patient safety in bariatric surgery.


Assuntos
Cavidade Abdominal , Cirurgia Bariátrica , Laparoscopia , Lesões do Sistema Vascular , Humanos , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/etiologia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Cirurgia Bariátrica/efeitos adversos , Instrumentos Cirúrgicos/efeitos adversos
12.
World Neurosurg ; 180: 70, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37741327

RESUMO

Intraoperative rupture is the most important complication of aneurysm surgery1-5 and occurs in 3 different stages: premature (before dissection), dissection, and clipping.5 We present a video of premature rupture and its management (Video 1). A 45-year-old patient presented with subarachnoid hemorrhage originating from a dorsal internal carotid artery (ICA) aneurysm of the communicating segment. Due to our sufficient experience, we preferred direct clipping in this case. The Sylvian fissure could only be partially opened due to excessive adhesions. During retraction of the frontal lobe, severe bleeding occurred. This was a premature rupture since neither the aneurysm nor the ICA had yet been seen. While aspirating the bleeding just over the rupture site with the left hand, the ICA was explored with the right hand and a temporary clip was placed. The bleeding continued, though it decreased. The aneurysm dome was rapidly explored with 1 hand, and a pilot clip was placed on the dome to stop the bleeding. Immediately afterwards, the aneurysm neck was dissected and clipped parallel to the ICA with a sideward clip. The temporary clip and pilot clip were removed. The temporary occlusion time was 7 minutes and 40 seconds. Postoperative angiogram confirmed complete aneurysm occlusion. The patient discharged with normal neurologic examination. In the literature review including 10,540 cases,1 the mean incidence of IOR is 16.6%. Therefore every neurosurgeon should be prepared for this important complication and know its management well. This case reminds us once again the golden rule of aneurysm surgery: proximal control first.


Assuntos
Doenças das Artérias Carótidas , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/complicações , Sonhos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/cirurgia , Angiografia/efeitos adversos , Doenças das Artérias Carótidas/cirurgia , Instrumentos Cirúrgicos/efeitos adversos
13.
Neurol Med Chir (Tokyo) ; 63(10): 482-489, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37648536

RESUMO

Delayed foreign body reactions to either or both clipping and coating materials have been reported in several small series; however, studies in the titanium clip era are scarce. This study aims to survey the contemporary status of such reactions to titanium clips and coating materials. Among patients who received a total of 2327 unruptured cerebral aneurysmal surgeries, 12 developed delayed intraparenchymal reactions during outpatient magnetic resonance imaging (MRI) follow-up. A retrospective investigation was conducted. The patients' average age was 58.6 (45-73) years, and 11 were women. The aneurysms were located in the middle cerebral artery (n = 7), internal carotid artery (n = 4), or anterior communicating artery (AComA, n = 1). In 10 patients, additional coating with tiny cotton fragments was applied to the residual neck after clipping with titanium clips; however, only the clipping with titanium clips was performed in the remaining two. The median time from surgery to diagnosis was 4.5 (0.3-60) months. Seven (58.3%) patients were asymptomatic, and three developed neurological deficits. MRI findings were characterized by a solid- or rim-enhancing lobulated mass adjacent to the clip with surrounding parenchymal edema. In 11 patients, the lesions reduced in size or disappeared; however, in one patient, an AComA aneurysm was exacerbated, necessitating its removal along with optic nerve decompression. In conclusion, cotton material is a strongly suspected cause of delayed foreign body reactions, and although extremely rare, titanium clips alone may also induce such a reaction. The prognosis is relatively good with steroid therapy; however, caution is required when the aneurysm is close to the optic nerve, as in AComA aneurysms.


Assuntos
Corpos Estranhos , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Titânio , Estudos Retrospectivos , Instrumentos Cirúrgicos/efeitos adversos , Reação a Corpo Estranho , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia
14.
Mar Drugs ; 21(6)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37367649

RESUMO

Sodium alginate (SALG) is a substance derived from brown seaweed that has been shown to reduce blood pressure (BP). However, its effects on renovascular hypertension caused by 2-kidney, 1-clip (2K1C) are not yet clear. Previous research suggests that hypertensive rats have increased intestinal permeability, and that SALG improves the gut barrier in inflammatory bowel disease mouse models. Therefore, the goal of this study was to determine whether the antihypertensive effects of SALG involve the intestinal barrier in 2K1C rats. Rats were fed either a 1.0% SALG diet or a control diet for six weeks after being subjected to 2K1C surgery or a sham operation. The systolic BP was measured weekly, and the mean arterial BP was measured at the end of the study. Intestinal samples were taken for analysis, and plasma lipopolysaccharide (LPS) levels were measured. The results showed that BP in 2K1C rats was significantly higher than in SHAM rats when fed CTL, but not when fed SALG. The gut barrier in 2K1C rats was improved by SALG intake. Plasma LPS levels also differed depending on the animal model and diet. In conclusion, dietary SALG may alleviate 2K1C renovascular hypertension by altering the gut barrier.


Assuntos
Hipertensão Renovascular , Camundongos , Ratos , Animais , Pressão Sanguínea , Hipertensão Renovascular/tratamento farmacológico , Hipertensão Renovascular/etiologia , Alginatos/farmacologia , Lipopolissacarídeos/farmacologia , Rim , Modelos Animais de Doenças , Instrumentos Cirúrgicos/efeitos adversos
15.
Int J Cardiol ; 388: 131112, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37343789

RESUMO

BACKGROUND: Although infective endocarditis (IE) represents a unique model of thrombo-inflammatory disease, the most frequent early complications of surgical valve replacement (SVR) in IE population are coagulopathy and bleeding. The hemostatic capacity and procedure-related coagulation disorders of IE patients undergoing SVR are unknown. The aims of this study were to test periprocedural hemostasis in IE patients undergoing urgent SVR, and to assess the association between disorders of hemostasis and early bleeding as well as with thromboembolic events. METHODS: A prospective, two-center, hypothesis generating, observational study was performed between Dec 2017 and Jan 2020. Periprocedural hemostasis of IE patients was assessed using Total Thrombus-formation Analysis System (T-TAS Plus) within 24 h before and 72 h post SVR. RESULTS: Overall, 25 patients with active IE undergoing urgent SVR were tested. Hemostatic capacity of IE patients was significantly impaired pre-SVR as well as post-SVR compared to normal values, in most aspects of T-TAS assays under high and low shear forces, including prolonged activation of coagulation (T10), final clot formation (OT) and clot strength (AUC30). Post-SVR T-TAS results were significantly associated with early bleeding and with red blood cell, platelet, and fresh frozen plasma administration. No association with thrombo-embolic events was found. CONCLUSIONS: Patients with active IE undergoing urgent SVR have significantly reduced hemostatic capacity before and after SVR. Hemostatic insufficiency post-SVR is related to bleeding and blood products transfusion. T-TAS may be helpful in assessment of periprocedural hemostasis in patients with IE undergoing SVR.


Assuntos
Endocardite Bacteriana , Endocardite , Transtornos Hemostáticos , Hemostáticos , Humanos , Estudos Prospectivos , Hemorragia/etiologia , Endocardite/diagnóstico , Endocardite/cirurgia , Transtornos Hemostáticos/complicações , Instrumentos Cirúrgicos/efeitos adversos
16.
BJS Open ; 7(3)2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37352873

RESUMO

BACKGROUND: Safe primary entry at laparoscopy could present challenges in obese patients. Various techniques have been proposed in previous studies, however, the characteristics of the actual device utilized may be more influential than the technique in achieving successful abdominal entry in patients with increased BMI. METHODS: This systematic review and meta-analysis included both randomized and non-randomized studies gathered with no date filters from MEDLINE, Embase, Scopus, Web of Science and Clinicaltrials.gov. PRISMA guidelines underpinned the conduct and reporting of the review. The meta-analysis of proportions was conducted using a generalized linear mixed model and analyses included random-effects models. The primary outcome was the proportion of first access vascular and visceral injuries incurred in the process of laparoscopic abdominal surgery in patients with a BMI >30 kg/m2. Subgroup analysis was performed for optical versus non-optically enabled devices. RESULTS: In total, 5403 patients were analysed across 13 observational studies with a mean BMI of 45.93 kg/m2. In 216 patients from two randomized studies, the mean BMI was 39.92 kg/m2. The overall incidence using a random-effects model was 8.1 per 1000 events of visceral and vascular injuries (95 per cent c.i. 0.003 to 0.024). Heterogeneity was statistically significant at I2 = 80.5 per cent (69.6 per cent; 87.5 per cent, P< 0.0001). In a subgroup analysis, a tendency towards reduced injuries when optical devices were employed was observed with one per 100 injuries in these trocars (95 per cent c.i. 0.001 to 0.018) versus four per 100 (95 per cent c.i. -0.019 to -0.102) in non-optically enabled devices. CONCLUSION: Injuries during primary laparoscopic entry undertaken in obese patient groups are uncommon. Due to considerable heterogeneity in the small number of examined studies, evidence was insufficient and largely of low quality to ascribe differences in the incidence of injuries to the characteristics of the primary entry trocar utilized.


Assuntos
Laparoscopia , Lesões do Sistema Vascular , Humanos , Laparoscopia/métodos , Abdome , Obesidade/complicações , Instrumentos Cirúrgicos/efeitos adversos
17.
Scand J Gastroenterol ; 58(10): 1173-1179, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37128690

RESUMO

BACKGROUND AND STUDY AIMS: The optimal treatment for gastric varices (GVs) is a topic that remains definite for this study. This study compared the clinical outcomes of clip-assisted endoscopic cyanoacrylate injection (clip-ECI) to conventional endoscopic cyanoacrylate injection (con-ECI) for the treatment of GVs with a gastrorenal shunt. PATIENTS AND METHODS: Data were collected retrospectively in five medical centers from 2015 to 2020. The patients were treated with con-ECI (n = 126) or clip-ECI (n = 148). Clinical characteristics and procedural outcomes were compared. Patients were followed until death, liver transplantation or 6 months after the treatment. The primary outcome was rebleeding, and the secondary outcome was survival. RESULTS: There were no significant differences in age, sex, etiology, shunt diameter and Child-Pugh classification between the two groups. Fewer GVs obliteration sessions were required in the clip-ECI group than in the con-ECI group (p = 0.015). The cumulative 6-month rebleeding-free rates were 88.6% in the clip-ECI group and 73.7% in the con-ECI group (p = 0.002). The cumulative 6-month survival rates were 97.1% in the clip-ECI group and 94.8% in the con-ECI group (p = 0.378). CONCLUSIONS: Compared with con-ECI, clip-ECI appears more effective for the treatment of GVs with a gastrorenal shunt, which required less sessions and achieved a higher 6-month rebleeding-free rate.


Assuntos
Cianoacrilatos , Varizes Esofágicas e Gástricas , Humanos , Cianoacrilatos/efeitos adversos , Varizes Esofágicas e Gástricas/complicações , Estudos Retrospectivos , Resultado do Tratamento , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Recidiva Local de Neoplasia , Instrumentos Cirúrgicos/efeitos adversos , Recidiva
18.
BMC Oral Health ; 23(1): 233, 2023 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-37085833

RESUMO

BACKGROUND: Among the post-surgical complications of lower wisdom teeth surgery, swelling is considered by patients one of the most impairing, with both social and biological influences and impacting patients' quality of life. Aim of the study was to evaluate the swelling following the osteotomy when performed with drilling burs versus piezo-electric instruments in the mandibular impacted third molar extraction, using a facial reconstruction software. MATERIALS AND METHODS: A randomized, split-mouth, single-blind study was conducted on patients, ranging between 18 and 40 years of age, requiring lower third molars extraction and referred at the Oral Surgery Unit of the School of Dentistry of the University of Messina. Twenty-two patients were recruited during an 8 months period according to the following criteria: good general health conditions; bilateral, symmetrical, impacted third molars; no use of medication that would influence or alter wound healing; no temporomandibular joint disorder history; no smoking. All patients underwent bilateral surgical removal. For each patient, a facial scan was obtained prior to the surgical procedures. The two extractions were conducted performing, in a randomized way, osteotomy with rotatory burs or use of piezo surgical instruments. Facial scans were repeated at 3 and 7 days after the surgical procedures. Volumetric differences were calculated via superimposition using a dedicated software. The data obtained were processed using paired t-test. RESULTS: The results obtained from our study showed no significant differences between two groups regarding post-operative swelling. To the best of our knowledge, this study represents the first experience of using an objective method that can be reproducible on the collection of patients' clinical parameters. CONCLUSIONS: The 3D digital analysis, in the evaluation of facial swelling, is a technique of simple application, objective, reproducible, reliable, decreasing the variables of error. Based on these data, it is possible to conclude that piezo surgery is a safe way for performing the osteotomies during third molar surgery. However, regarding the post-operative swelling, it does not show an advantage over classical rotary instruments. TRIAL REGISTRATION: Registered on ClinicalTrials.gov (ID: NCT05488028, on 04/08/2022). Approved by Ethical Committee of Messina: (ID 01-2020, on 27/04/2020).


Assuntos
Dente Serotino , Dente Impactado , Humanos , Dente Serotino/cirurgia , Dor Pós-Operatória/etiologia , Qualidade de Vida , Método Simples-Cego , Piezocirurgia/métodos , Dente Impactado/cirurgia , Extração Dentária/efeitos adversos , Extração Dentária/métodos , Edema/etiologia , Instrumentos Cirúrgicos/efeitos adversos
19.
Langenbecks Arch Surg ; 408(1): 152, 2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069276

RESUMO

OBJECTIVE: Direct insertion of the trocar is an alternative method to Veress needle insertion for the creation of pneumoperitoneum. We conducted a systematic review and meta-analysis to compare these two entry closed techniques. DATA SOURCE: A systematic review of the literature was done on PubMed, MEDLINE, Embase, Scopus, and EBSCO. METHODS: The literature search was constructed until May 01, 2022, around search terms for "Veress," "direct trocar," "needle," "insertion," and "laparoscopic ways of entry." This systematic review was reported according to the PRISMA Statement 2020. RESULTS: Sixteen controlled trials (RCTs) and 5 observational studies were included in the systematic review. We found no significant differences in the risk of major complication during the access manoeuvres between DTI and VN: bowel injuries (OR = 0.76, 95% CI: 0.24-2.36, P = 0.63), major vascular injuries (OR = 1.74, 95% CI 0.56-5.38, P = 0.34), port site hernia (OR = 2.41, 95% CI: 0.28-20.71, P = 0.42). DTI has a lower risk of minor complications such as subcutaneous emphysema (OR = 5.19 95% CI: 2.27-11.87, P < 0.0001), extraperitoneal insufflation (OR = 5.93 95% CI: 1.69-20.87, P = 0.006), omental emphysema (OR = 18.41, 95% CI: 7. 01-48.34, P < 0.00001), omental bleeding (OR = 2.32, 95% CI: 1.18-4.55, P = 0.01), and lower number of unsuccessful entry or insufflation attempts (OR = 2.25, 95% CI: 1.05-4.81, P = 0.04). No significant differences were found between the two groups in terms of time required to achieve complete insufflation (MD = - 15.53, 95% CI: - 91.32 to 60.27, P = 0.69), trocar site bleeding (OR = 0.66, 95% CI, 0.25-1.79, P = 0.42), and trocar site infection (OR = 1.19, 95% CI, 0.34-4.20, P = 0.78). CONCLUSION: There were no statistically significant differences in the risk of major complications during the access manoeuvres between DTI and VN. A lower number of minor complications were observed in DTI compared with those in Veress access.


Assuntos
Laparoscopia , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Pneumoperitônio Artificial/efeitos adversos
20.
Int Urol Nephrol ; 55(6): 1467-1475, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36976419

RESUMO

BACKGROUND: Robotic-assisted laparoscopic prostatectomy (RALP) is the most preferred intervention for the management of prostatic malignancy worldwide. Hem-o-Lok clips (HOLC) are widely used for haemostasis and lateral pedicle ligation. These clips are prone to migrate and lodge at the anastomotic junction as well as inside the bladder causing lower urinary tract symptoms (LUTS) secondary to bladder neck contracture (BNC) or bladder calculi. The objective of this study is to describe the incidence, clinical presentation, management, and outcome of HOLC migration. METHODOLOGY: Retrospective analysis of the database of Post RALP patients who developed LUTS secondary to HOLC migration was done. Cystoscopy findings, number of procedures required, number of HOLC removed intra-operatively, and follow-up of the patients was reviewed. RESULTS: The incidence of HOLC migration requiring intervention was 1.78% (9/505). The mean age of the patient, BMI, Pre-operative Serum PSA were 62.8 years, 27.8 kg/m2, and 9.8 ng/mL, respectively. The mean duration of appearance of symptoms due to HOLC migration was 9 months. Two patients presented with Haematuria and 7 presented with LUTS. Seven patients required a single intervention while 2 required up to 6 procedures for recurrent symptoms secondary to recurrent HOLC migration. CONCLUSION: HOLC use in RALP may present with migration and associated complications. HOLC migration is associated with severe BNC and may require multiple endoscopic interventions. Severe dysuria and LUTS not responding to medical management should be treated using an algorithmic approach and there should be a low threshold for performing cystoscopy and intervention in these cases to improve outcomes.


Assuntos
Migração de Corpo Estranho , Laparoscopia , Sintomas do Trato Urinário Inferior , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Pessoa de Meia-Idade , Bexiga Urinária/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Migração de Corpo Estranho/epidemiologia , Migração de Corpo Estranho/etiologia , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Sintomas do Trato Urinário Inferior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...